Formula sheet: physicsSecondary school, year 2 · Resistivity and rated data
Resistance from rated data
Explanation
: rated voltage; : rated power.
- rated voltage
- rated power
Examples
Example 1: simple
What is the resistance of a copper wire (mm²/m) 20 m long with a cross-section of 2 mm²? Give the answer in .
- We use the relation: .
- Substituting the data: .
Answer: 0.17 Ω
Example 2: medium
A heater is marked 230 V, 460 W. What is its resistance? Give the answer in .
- We use the relation: .
- Substituting the data: .
Answer: 115 Ω
Example 3: harder
A 230 V, 460 W heater is connected to 115 V (resistance unchanged). What power does it have now? Give the answer in W.
- We use the relation: , .
- Substituting the data:
.
Answer: 115 W